SWIFT© Flush Doors are of guaranteed quality. Flush Doors are made in varying constructions & thickness without impairing efficiency to meet exactly the security needs for the building. The wide range of choice in quality of material like: Timber and adhesive used, processing techniques including vacuum impregnation preservative chemical (CCA) treatment enable manufacturer to offer a Flush Door capable of giving efficient and needed protection. Excellent quality Flush Doors are manufactured from 100% Pinewood (Without treatment) & selected Hardwood timber with vacuum impregnation preservative chemical (CCA) treated and are of Solid core construction with BN & BD type. Flush Doors are framed in seasoned battens, both the stiles are made with one finger joint, pressed at high pressure & controlled temperature and bonded with BWP grade phenol formaldehyde synthetic adhesive conforming to IS: 848-2006. Swift Flush Doors combine simplicity, pleasing appearance, clean & beautiful finish.

SALIENT FEATURES

  • Boiling water proof.
  • Borer, termite & powder free.
  • Accuracy & stability in dimension.
  • No warping & delamination when subjected to change in atmospheric condition.
  • Excellent screw holding capacity.
  • Sufficient strength in the sheathing material to resist normal knocks and blows.
  • It is economical in comparisons to the other products due to durability.
  • STANDARD SIZE (IN MM)

  • 1905 X 700 , 1905 X 800 , 1905 X 900
  • 2005 X 700 , 2005 X 800 , 2005 X 900 and as per specific orders.
  • STANDARD THICKNESS (IN MM)

  • 25, 30, 35 and as per specific orders.
  • USES

  • Widely used for entrance and living area doors, ideal where splashing is common such as toilet, bathrooms, balcony doors etc.
  • PROPERTIES

    TESTSREQUIREMENTRESULT OBTAINED
    Dimension & Suareness
    Height,mm
    Width,mm
    Thickness,mm,Min/Max
    Variation in thickness between any two points
    Squareness,mm
    Tolerance:
    ±5 mm
    ±5 mm
    ±1 mm
    Max.0.8
    Deviation not more than 1mm per 500mm length

    ± 2 mm
    ± 2 mm
    ± 0.50 mm
    0.50 mm
    0.45 mm
    General flatness
    Twist,mm Max. 6Less than 6 mm
    Cupping,mm Max. 6Less than 6 mm
    Warping, mm Max. 6Less than 6 mm
    Local planeness,mm Max. 0.50.18
    Impact indentation No cracking, tearing or delamination. Indentation depth, max 0.2mm No cracking, tearing or delamination.0.14mm
    Flexure Test
    (deflection in mm)
    15 minutes after 50 kg
    3 minutes after load removal
    Deflection at maximum load not greater than 1/30th of length or 1/15th of width, whichever is less. Residual deflection not greater than 1/10 of maximum deflection. MD: Less than 1/30th of length & 1/15th of width. RD: Less than 1/10th of MD
    Edge loading Test
    (deflection in mm)
    After 15 minutes of 100 kg loading
    5 minutes after load removal
    Lateral buckling
    Deflection at maximum load not greater than 5 mm. Residual deflection after removal of load not greater than 0.5mm. Not more than 2mm during loading. No residual buckling after load removal. MD: Less than 5mm.
    RD:Less than 0.5mm
    Lateral Buckling:0.1mm
    Conforms to the requirement
    Shock Resistance Test
    Soft & light body impact
    Soft & heavy body impact
    No visible damage
    No visible damage
    Conforms to the requirement
    Conforms to the requirement
    Slamming Test No visible damage after 50 drops.Conforms to the requirement
    Glue adhesion Test No delamination/ No single delamination of more than 50mm in length & more 3mm in depthConforms to the requirement
    End immersion Test No delamination 8 cycle-1 day wet & 1 day dry Conforms to the requirement
    Knife Test Minimum Pass standardPass Standard
    Screw withdrawal Test Not less than 1000 N Surface condition: No visible damage to the surface either by delamination or extra chipping off3000 N
    Conforms to the requirement
    Buckling test
    (deflection in mm)
    After 5 minutes of 40 kg loading
    15 minutes after load removal
    No deterioration
    Initial Deflection not greater than 50mm Residual deformation after 15 minutes of unloading not greater than 5mm
    Conforms to the requirement
    Misuse test No permanent deformation of the fixing or any other part of the door set in hindering its normal working after the test.Conforms to the requirement
    Varying humidity test No visible warping, twisting or delamination.
    Maximum departure from the general planeness not more than 0.1mm Recovery- At least 90% of the change in dimension.
    Conforms to the requirement